Created with Pixso. Agilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump Maintenance

Agilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump Maintenance

Nombre De La Marca: Agilent
Número De Modelo: 5063-6589
Información Detallada
Lugar de origen:
CHINA&JAPAN
Marca:
Agilente
Número de pieza:
5063-6589
Nombre del producto:
Sello de pistón de PTFE
Tipo de producto:
Sello de repuesto de bomba HPLC
Material:
PTFE
Cantidad del paquete:
2 piezas por paquete
Aplicación principal:
Mantenimiento de bombas LC y HPLC
Familias del sistema primario:
Agilent series 1100, 1200 y 1260
Posición de instalación:
Área de sellado del pistón de la bomba y del cabezal de la bomba
Propósito del mantenimiento:
Reemplazo de sellos de pistón desgastados o con fugas
Requisito de pedido:
Confirmar el número de módulo y el número de pieza del sello existente
Resaltar:

Agilent PTFE piston seal for HPLC pump

,

HPLC pump maintenance piston seal

,

PTFE piston seal 2-pack

Descripción del Producto
Agilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC
Agilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump MaintenanceAgilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump MaintenanceAgilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump Maintenance

The Agilent 5063-6589 PTFE Piston Seal is a replacement sealing component supplied in a convenient package of two pieces. It is intended for compatible Agilent liquid chromatography pumps and related LC modules, including commonly listed 1100, 1200, and 1260 Series systems. The seal is installed around the reciprocating piston area of the pump head, where it helps contain the mobile phase and maintain dependable liquid delivery during chromatographic analysis.

A worn piston seal may contribute to solvent leakage, unstable pressure, reduced pump efficiency, or inconsistent flow. Replacing the seal during scheduled maintenance can help restore the sealing interface and support normal pump operation. Part number 5063-6589 is identified by Agilent as a replacement PTFE piston seal and is supplied as two seals per package. Buyers should verify the instrument model, pump module number, application chemistry, and existing seal part number before ordering.


Key Product Information
Item Details
Brand Agilent
Part Number 5063-6589
Product Name PTFE Piston Seal
Product Type HPLC pump replacement seal
Material PTFE
Package Quantity 2 pieces per pack
Main Application LC and HPLC pump maintenance
Primary System Families Agilent 1100, 1200 and 1260 Series
Installation Position Pump piston and pump-head sealing area
Maintenance Purpose Replacement of worn or leaking piston seals
Ordering Requirement Confirm module number and existing seal part number

Agilent identifies 5063-6589 as a replacement PTFE piston seal for LC pumps and autosamplers. Additional compatibility listings include selected G1310, G1311, G1312, G1376, G2226 and G4302 modules, although final compatibility should always be confirmed against the exact instrument configuration.


Cause
Why Does an HPLC Piston Seal Need Replacement?

An HPLC pump operates through repeated piston movement. During operation, the piston moves through the sealing area while the pump draws in and delivers mobile phase under controlled pressure. The seal is therefore exposed to continuous mechanical movement, solvent contact, pressure cycles and routine system operation.

Over time, the sealing surface may wear or become less effective. Seal condition can also be affected by contamination, deposits, an unsuitable solvent environment, piston damage, improper installation or extended service intervals. Agilent technical material notes that seal design and spring force influence pump-head sealing, air entry, pressure ripple and abrasion between the piston and seal.

Common Causes of Seal Wear
Cause Possible Effect
Normal mechanical wear Gradual reduction in sealing performance
Long operating hours Increased possibility of leakage or pressure instability
Abrasive particles Accelerated wear on the seal or piston surface
Buffer crystallization Deposits around the piston and seal area
Inadequate flushing Residue remaining inside the pump head
Damaged piston surface New seals may wear rapidly after installation
Incorrect seal type Poor compatibility with the instrument or application
Improper installation Distortion, leakage or premature failure
Dry pump operation Increased friction at the sealing interface
Delayed maintenance Progressive pump performance problems

Typical Symptoms of a Worn Piston Seal

The following symptoms may indicate that the pump-head sealing area requires inspection. These symptoms can also be caused by other flow-path components, so troubleshooting should include the piston, check valves, capillaries, fittings, purge valve and solvent-supply path.

Observed Symptom Possible Relationship to the Seal
Visible solvent near the pump head Seal may no longer contain the mobile phase effectively
Unstable pressure trace Air entry, leakage or flow-path instability may be present
Pressure lower than expected The pump may not be delivering the required volume efficiently
Flow inconsistency Pump compression and delivery may be affected
Increased pressure ripple Sealing or inlet-delivery conditions may require inspection
Frequent air bubbles Leakage or poor priming may be present
Salt deposits around pump head Buffer may have leaked and dried near the seal area
Reduced analytical repeatability Unstable mobile-phase delivery may affect the method
Abnormal pump noise The pump may require inspection and preventive maintenance
Recurring leak after seal replacement The piston or installation condition may also be damaged

Agilent publishes a specific seal-wear procedure for 1260 isocratic and quaternary pumps and lists part number 5063-6589 as the PTFE piston seal used in that service context.


Solution
Replace the Worn Seal with the Correct 5063-6589 PTFE Piston Seal

When inspection confirms that the existing seal is worn, contaminated or leaking, replacement with the correct part can restore the sealing interface between the piston and pump head. The 5063-6589 package contains two PTFE piston seals, making it suitable for planned servicing where two sealing positions are involved or where a second seal is required as a maintenance spare, depending on the pump module.

Recommended Maintenance Approach
Step Recommended Action
1 Record the LC system series and pump module number
2 Confirm the current seal part number before removal
3 Depressurize the system and follow the instrument service procedure
4 Inspect the pump head, piston and seal area
5 Remove contamination without scratching sealing surfaces
6 Replace damaged seals with the specified part
7 Reassemble components in the correct orientation
8 Prime the pump with an appropriate solvent
9 Follow the applicable seal wear-in procedure
10 Check for leakage, stable flow and normal pressure response
Important Service Note

Part number 5063-6589 is described in Agilent service documentation as a standard seal. Agilent also warns that the wear-in procedure intended for 5063-6589 should not be applied to the different normal-phase seal identified as 0905-1420, because the procedure can damage that alternative seal. The installed seal type and application must therefore be confirmed before maintenance.


Product Advantages
Advantage Customer Benefit
Identified part number Simplifies replacement-part verification
PTFE sealing material Intended for compatible LC pump sealing applications
Two-piece package Convenient for scheduled maintenance requirements
Compatible system coverage Suitable for multiple commonly used Agilent LC families
Maintenance-focused design Supports replacement of worn pump seals
Compact spare part Easy to store in a laboratory maintenance inventory
Clear application Used around the pump piston sealing area
Preventive maintenance value Helps reduce avoidable downtime caused by delayed replacement
Internationally recognized brand Suitable for laboratories operating Agilent LC equipment
Easy inquiry process Buyers can confirm compatibility using module and part numbers

Specifications
General Specifications
Specification Value
Manufacturer/Brand Agilent
Manufacturer Part Number 5063-6589
Component Piston Seal
Seal Material PTFE
Color Commonly supplied as a black piston seal
Package Standard 2 pieces per pack
Equipment Category Liquid chromatography equipment
Instrument Type LC/HPLC pump system
Component Function Dynamic sealing around the reciprocating pump piston
Replacement Type Routine maintenance and repair component
Primary Application Pump-head sealing and liquid-delivery maintenance
Installation Method Installed according to the applicable pump service procedure
Condition Confirm with supplier before purchase
Origin Confirm according to the actual supplied batch
Warranty Subject to supplier quotation and sales terms
Shipping Method Express courier, air shipment or consolidated order
Compatibility Confirmation Required before order placement

The manufacturer product page describes 5063-6589 as a replacement PTFE piston seal for Agilent LC pumps and autosamplers. Independent chromatography-parts listings identify the package as two seals per pack.


Commonly Listed System Compatibility
System or Module Compatibility Reference
Agilent 1050 Series Commonly listed
Agilent 1100 Series Commonly listed
Agilent 1120 Series Commonly listed
Agilent 1200 Series Commonly listed
Agilent 1220 Series Commonly listed
Agilent 1260 Series Commonly listed
G1310A Commonly listed
G1310B Commonly listed
G1311A Commonly listed
G1311B Commonly listed
G1311C Commonly listed
G1312A Commonly listed
G1312B Commonly listed
G1312C Commonly listed
G1376A Commonly listed
G2226A Commonly listed
G4302A Commonly listed

Compatibility references vary by distributor and service configuration. Buyers should not select the seal only by the general system name. The complete module number, pump type, serial-number range, existing seal number and application should be checked before purchase.


Package Information
Item Description
Package Contents Two PTFE piston seals
Package Unit 2/PK
Part Number Marking 5063-6589
Recommended Storage Clean, dry and protected from contamination
Handling Avoid touching the functional sealing surface unnecessarily
Packaging Verification Inspect label and quantity upon receipt
Pre-Installation Check Confirm that the seal has not been deformed or contaminated
Inventory Recommendation Store by part number and compatible module

Agilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump MaintenanceAgilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump MaintenanceAgilent 5063-6589 PTFE Piston Seal 2-Pack for 1100/1200/1260 HPLC Pump Maintenance
Application

The Agilent 5063-6589 piston seal is used as a service component in compatible liquid chromatography equipment. Its main application is within the pump-head assembly, where stable solvent delivery is essential to the performance of an LC or HPLC method.

Typical Application Environments
Application Environment Use of the Product
Pharmaceutical laboratory Maintenance of HPLC pump systems used for analytical testing
Chemical analysis laboratory Replacement of worn seals in solvent-delivery modules
University research facility Routine maintenance of shared chromatography equipment
Food-testing laboratory Pump servicing for chromatographic quality analysis
Environmental laboratory Maintenance of instruments used for sample analysis
Contract testing laboratory Preventive maintenance to support instrument availability
Quality-control department Restoration of reliable pump operation
Instrument service company Repair and maintenance of compatible LC modules
Laboratory equipment distributor Replacement-part supply for chromatography users
In-house maintenance team Planned servicing of HPLC pump assemblies

Suitable Maintenance Situations

The product may be considered when:

  • The existing seal carries part number 5063-6589.
  • The service manual specifies a PTFE piston seal.
  • Solvent is visible around the pump-head sealing area.
  • Preventive maintenance is due according to laboratory procedure.
  • The piston seal has been removed during pump-head servicing.
  • Pump pressure remains unstable after basic priming and fitting checks.
  • A maintenance kit requires the 5063-6589 seal.
  • A laboratory needs a spare two-piece package for future service.
  • An instrument service company is repairing a compatible LC pump.
  • The buyer has confirmed the exact pump module and seal specification.

How It Works

An HPLC pump uses one or more reciprocating pistons to draw mobile phase from the solvent supply and deliver it into the analytical flow path. The piston repeatedly moves through the pump-head sealing area. The piston seal forms a controlled interface around the moving piston so that mobile phase remains within the pump chamber while the piston continues its intake and delivery strokes.

During the intake stroke, the pump chamber receives mobile phase. During the delivery stroke, the piston pressurizes and moves the liquid toward the downstream flow path. The seal must maintain contact with the piston without preventing its repeated movement. A suitable seal therefore contributes to liquid containment, pressure stability and consistent pump operation. Agilent technical information explains that incorrect seal characteristics can contribute to air entering the pump head, pressure ripple or excessive abrasion between the seal and piston.

Working Sequence
Stage Pump Activity Seal Function
1. Solvent intake Piston movement creates chamber volume Seal limits liquid escape around the piston
2. Chamber filling Mobile phase enters the pump head Seal maintains the piston interface
3. Compression Piston reduces chamber volume Seal helps contain pressurized liquid
4. Delivery Mobile phase moves into the flow path Seal supports controlled pump output
5. Repetition Pump cycle repeats continuously Seal operates under repeated motion
6. Maintenance Wear is inspected during service Seal is replaced when performance declines

Why Seal Condition Matters

A piston seal is a small component, but it works directly within the pump’s liquid-delivery mechanism. When the sealing interface is in good condition, the pump can operate with fewer leakage-related interruptions. When the seal becomes worn, the pump may require more frequent priming, cleaning or troubleshooting.

Replacing only the seal may not resolve every pump problem. The piston surface, check valves, purge valve, fittings, solvent filters, capillaries and degassing system may also affect flow and pressure. A complete diagnosis should therefore be performed before replacement, particularly when leakage continues after a new seal has been installed.


How to Choose

Selecting an HPLC piston seal requires more than matching the general instrument series. Similar-looking seals can be designed for different solvents, pressure ranges, pump modules or service procedures.

Selection Checklist
Selection Point What to Confirm
Brand Agilent
Part number 5063-6589
Component type PTFE piston seal
Package requirement Two seals per pack
System family 1100, 1200, 1260 or another listed family
Exact module For example, G1310, G1311 or G1312 variant
Current installed seal Confirm the number printed in the service record
Application chemistry Reversed-phase, normal-phase or special solvent application
Service procedure Correct instructions for the exact pump module
Piston condition No unacceptable scratches, residue or damage
Supply type Original branded part or compatible replacement
Required documents Quotation, invoice, packing list or inspection photos

Step 1: Match the Exact Part Number

The most reliable starting point is the number on the existing packaging, maintenance record, spare-parts list or instrument service manual. For this product, the required number must be 5063-6589.

Do not order only by appearance. Different piston seals can have similar dimensions or colors while using different materials and operating requirements.


Step 2: Confirm the Pump Module

“1100 Series” or “1260 Series” alone may not provide enough information. Send the complete module number, such as G1311A, G1311B, G1311C, G1312A, G1312B or G1312C, together with a pump nameplate photograph. These module families are commonly included in compatibility listings for 5063-6589.


Step 3: Confirm the Seal Chemistry

Part number 5063-6589 is identified as a PTFE piston seal. Agilent distinguishes this standard seal from the different normal-phase seal 0905-1420. The two should not be confused, especially when applying a seal wear-in procedure.


Step 4: Inspect the Piston

A damaged piston can shorten the service life of a new seal. Before installation, inspect the piston for scratches, residue, chips or visible wear. Replacing the seal without addressing piston damage may result in recurring leakage.


Step 5: Confirm Package Quantity

The standard listing for 5063-6589 is two seals per package. Confirm the number of packages required according to the pump configuration, maintenance plan and desired spare inventory.


Step 6: Clarify Supply Requirements

Before ordering, specify whether your project requires:

Requirement Information to Provide
Brand requirement Original Agilent only or acceptable compatible option
Condition New and unused
Quantity Number of two-piece packages required
Delivery destination Country, city and postal code
Shipping method Courier, air freight or consolidation
Documentation Commercial invoice, packing list or certificate request
Urgency Required delivery date
Compatibility evidence Module nameplate and old-part photographs

Installation and Maintenance Guidance

Installation should be performed by qualified laboratory personnel or an experienced chromatography service technician. The instrument must be depressurized, disconnected from hazardous solvent sources and serviced according to the applicable manufacturer procedure.

Before Installation
  • Confirm the exact instrument and pump module.
  • Check that the ordered part number is 5063-6589.
  • Prepare clean tools and an appropriate work area.
  • Flush hazardous or buffered mobile phase as required.
  • Release system pressure completely.
  • Wear suitable personal protective equipment.
  • Review the applicable pump service documentation.
  • Inspect the replacement seals before opening the pump head.
During Installation
  • Avoid scratching the piston or pump-head surface.
  • Do not contaminate the functional sealing surface.
  • Observe the correct seal orientation.
  • Use only the recommended installation tools.
  • Inspect the piston before installing the new seal.
  • Replace damaged supporting components when necessary.
  • Tighten components according to the relevant service procedure.
  • Do not mix components from different seal types.
After Installation
  • Prime the pump with a suitable solvent.
  • Check all fittings for leakage.
  • Follow the correct seal wear-in procedure where required.
  • Monitor pressure stability and pump operation.
  • Verify normal flow delivery before reconnecting the analytical column.
  • Record the maintenance date and installed part number.
  • Retain the second seal in clean, identified packaging when it is not immediately used.

Agilent’s 1100 pump support document states that the specified wear-in procedure applies to standard 5063-6589 seals and should not be used for the different normal-phase seal.


Quality-Control Recommendations
Inspection Point Recommended Check
Part number Confirm 5063-6589
Quantity Confirm two pieces per pack
Seal surface No visible damage or contamination
Packaging Clean and properly labeled
Existing piston No obvious scratches or deposits
Pump head Clean before reassembly
Leakage test No visible solvent leakage after installation
Pressure test Stable response under the applicable test method
Service record Record date, module and installed part
Spare storage Keep remaining seal sealed and identified

Ordering Information

For a fast and accurate quotation, provide the following information:

Required Information Example
Product part number 5063-6589
Product description PTFE piston seal, 2/PK
Instrument series Agilent 1100/1200/1260
Pump module G1311C or G1312B
Required quantity 3 packs
Supply requirement Original branded or compatible
Delivery country Customer’s destination country
Preferred shipping DHL, FedEx, UPS or consolidated shipment
Required date Target arrival date
Reference image Photograph of old seal packaging or module nameplate

Providing the complete module number helps prevent selection errors and allows compatibility to be checked before shipment.


FAQ
Q1: What is Agilent part number 5063-6589?

Agilent 5063-6589 is a replacement PTFE piston seal used in compatible liquid chromatography pump and related module applications. It is supplied in a package containing two seals and is used during preventive maintenance or pump-head repair.

Q2: Is 5063-6589 suitable for Agilent 1100, 1200 and 1260 systems?

It is commonly listed for 1100, 1200 and 1260 Series systems, as well as selected G1310, G1311 and G1312 pump modules. Compatibility must still be confirmed using the complete module number and existing part number.

Q3: How many seals are included in one package?

The standard package contains two PTFE piston seals. Buyers should order by package quantity rather than assuming that the quoted quantity refers to individual seals.

Q4: Is 5063-6589 the same as the normal-phase seal 0905-1420?

No. Agilent documentation distinguishes the standard 5063-6589 seal from the normal-phase application seal 0905-1420. The standard-seal wear-in procedure can damage the normal-phase seal, so the seal type must be verified before servicing.

Q5: What information should I provide before ordering?

Please provide part number 5063-6589, the complete pump module, instrument series, required quantity, supply preference and a photograph of the module nameplate or old package. This information supports accurate compatibility checking and quotation preparation.


Contact Us

Need a dependable source for Agilent 5063-6589 PTFE Piston Seals and other chromatography maintenance components?

Send us your inquiry with:

  • Required part number
  • HPLC system series
  • Complete pump module number
  • Required quantity
  • Original or compatible supply preference
  • Delivery country and postal code
  • Expected delivery date
  • Photos of the old part or instrument nameplate

Our sales team will review the information and prepare a clear quotation covering product description, package quantity, availability, shipping options and estimated delivery arrangements.

Contact us today for compatibility confirmation, bulk-order pricing and international shipment support.